Skip to main contentSkip to footer
    PVC Overlay / Roof Recovery

    Main Event Grapevine, TX

    Grapevine, TX
    Main Event / Entertainment

    A 45,900 sq ft PVC overlay on an active entertainment center, converting a failing ballasted EPDM system to a grease-resistant PVC membrane with zero operational disruption.

    Roof Size
    45,900 sq ft
    System
    50 mil PVC membrane overlay over existing EPDM
    Project Type
    PVC Overlay / Roof Recovery
    Completed
    Apr 2026

    About the Client

    Main Event is a family entertainment center featuring bowling, laser tag, arcade games, and dining. The Grapevine location operates seven days a week with consistent foot traffic, making any extended closure or disruption to operations a significant concern for management.

    Main Event Grapevine, TX project
    Main Event Grapevine, TX challenge

    The Challenge

    The existing roof was a ballasted EPDM system, meaning the membrane was held in place by river rock rather than being mechanically attached or adhered. The EPDM seams had failed over time, causing multiple leaks throughout the building. Beyond the immediate leak problems, the property owner needed a roofing solution that could withstand cooking grease from the facility's food service operations, as grease exposure will degrade many roofing membranes over time. The interior featured metal walls that required special detailing to properly terminate the new membrane system.

    Our Solution

    TriVAN recommended a PVC overlay that would address all of the client's requirements without the cost and disruption of a full tear-off. PVC membrane is inherently resistant to cooking grease, oils, and animal fats, making it the right choice for buildings with food service operations. The overlay approach allowed the existing EPDM to remain in place as a secondary layer while the new PVC membrane provided the primary waterproofing. The ballast rock needed to be removed to create a proper substrate for the overlay, and the interior metal walls required plywood encapsulation to provide a surface for membrane termination.

    Main Event Grapevine, TX solution
    Main Event Grapevine, TX execution

    Project Execution

    The installation began with removing the ballast rock from the entire 45,900 sq ft roof area. The rocks were vacuumed off the roof rather than shoveled, minimizing noise and debris that could impact building operations below. With the ballast removed and the existing EPDM exposed, crews installed plywood at the interior metal wall locations to create proper termination surfaces for the new membrane. The 50 mil PVC membrane was then installed as a complete overlay across the roof surface, with all penetrations, curbs, and perimeter details flashed according to manufacturer specifications. The entire project was completed while Main Event continued normal operations, with no closures or disruption to guests.

    Results & Outcomes

    The building now has a seamless PVC roof system that eliminates the leak problems caused by the failed EPDM seams. The grease-resistant properties of the PVC membrane provide long-term protection appropriate for a facility with food service operations. By using an overlay approach rather than tear-off, the project avoided the additional cost and waste of removing the existing system while still delivering a complete roofing solution. Most importantly, Main Event maintained continuous operations throughout the project with no impact to their business.

    Project Highlights

    45,900 sq ft overlay completed with zero disruption to operations
    Ballast rock vacuumed off roof for clean removal
    Grease-resistant PVC membrane for food service environment
    No tear-off required, complete overlay solution
    Plywood encapsulation at interior metal walls for proper membrane termination

    Key Takeaways

    Ballasted EPDM systems can be good candidates for overlay when the underlying membrane and insulation remain serviceable. Removing the ballast and installing a fully adhered or mechanically attached PVC system eliminates the seam-dependent waterproofing that often fails on older EPDM roofs. For buildings with food service, PVC's grease resistance is a critical consideration that should factor into any roof replacement or recovery decision. Proper planning and execution allows large-scale roof work to proceed without disrupting building operations.

    After

    Completed roof installation

    Main Event Grapevine, TX - After 1
    Main Event Grapevine, TX - After 2
    Main Event Grapevine, TX - After 3
    Main Event Grapevine, TX - After 4
    Main Event Grapevine, TX - After 5
    Main Event Grapevine, TX - After 6
    Main Event Grapevine, TX - After 7
    Main Event Grapevine, TX - After 8

    Ready to Start Your Project?

    Let's discuss your commercial roofing needs. Get a free assessment and discover how we can deliver exceptional results for your property.

    Call (877) 487-4826